LOCTITE LOCTITE MED3394 Resin - (1kg) White

New

LOCTITE MED3394 is a high-performance medical resin designed to endure sterilization and chemical exposure. It offers high heat resistance (HDT of 100°C), excellent biocompatibility (ISO 10993 and USP Class VI certified), low water absorption, and high dimensional accuracy. Available in sheer black and white, it is ideal for medical devices and laboratory equipment.

  • Endures multiple sterilization cycles
  • ISO 10993 and USP Class VI certified
  • High heat resistance: HDT 100C
loading...
Product No. loading...

LOCTITE MED3394 High-Performance Medical Resin

A Versatile Material for Medical Applications

LOCTITE MED3394 is a high-performance material specifically designed to endure multiple cycles of various sterilization methods while retaining its essential performance properties. This robust material offers excellent Heat Deflection Temperature (HDT) and tensile physical properties, making it highly resistant to chemical exposures, thus ideal for medical applications. Available in sheer black and white, LOCTITE MED3394 is biocompatible, meeting ISO 10993-5, -10, -11, and -23 standards, and is USP Class VI certified. It demonstrates high dimensional accuracy, toughness, and minimal water absorption, ensuring durability in demanding environments such as medical devices, laboratory equipment, and sterile devices.

Key Features of the LOCTITE MED3394:

  • High heat resistance, HDT of 100°C
  • Excellent biocompatibility, meeting multiple ISO standards
  • Low water absorption
  • High dimensional accuracy and toughness
  • Available in sheer black and white colors

Technical Specifications

Mechanical Properties

Property Unit Method Green Post Processed
Young’s Modulus MPa ASTM D638 1400 - 1700 2450 - 2650
Tensile Stress at Yield MPa ASTM D638 34 - 44 68 - 76
Elongation at Yield % ASTM D638 3.9 - 4.4 4.5 - 4.9
Tensile Stress at Break MPa ASTM D638 31 - 38 66 - 72
Elongation at Break % ASTM D638 25 - 39 9 - 16
Flexural Modulus MPa ASTM D790 - 2700
Flexural Elongation at Break % ASTM D790 >5 >5
IZOD Impact (Notched) J/m ASTM D256 - 24.5 - 27.5
Shore Hardness (3s) D ASTM D2240 66 75
HDT at 0.455 MPa °C ASTM D648 - 97 - 104
HDT at 1.82 MPa °C ASTM D648 - 82 - 94
Water Absorption (24hr) % ASTM D570 - 0.53
Water Absorption (48hr) % ASTM D570 - 0.69
Water Absorption (72hr) % ASTM D570 - 0.90
Solid Density g/cm³ ASTM D792 1.14 1.15
CTE (10°C to 60°C) µm/(m·K) ASTM E831 - 92.3

Biocompatibility

Property Method Green Post Processed
Cytoxocity ISO 10993-5 - Comply
Sensitization ISO 10993-10 - Comply
Acute Systemic Toxicity ISO 10993-11 - Comply
Irritation ISO 10993-23 - Comply
USP Class VI - - Comply

Liquid Properties

Property Unit Method Value
Viscosity at 25°C (77°F) cP ASTM D7867 1100 - 1250
Liquid Density g/cm³ ASTM D1475 1.09

Electrical Properties

Property Unit Method Green Post Processed
Volume Resistivity Ω·cm ASTM D257 - 1.05E +16
Surface Resistivity ASTM D257 - 4.0E +11
AC Relative Permittivity (Dielectric Constant) at 50 Hz (XY) none ASTM D150 - 3.8
AC Relative Permittivity (Dielectric Constant) at 1 kHz (XY) none ASTM D150 - 3.7
AC Relative Permittivity (Dielectric Constant) at 1 MHz (XY) none ASTM D150 - 3.4
AC Loss Characteristic (Dissipation Factor) at 50 Hz (XY) none ASTM D150 - 0.010
AC Loss Characteristic (Dissipation Factor) at 1 kHz (XY) none ASTM D150 - 0.010
AC Loss Characteristic (Dissipation Factor) at 1 MHz (XY) none ASTM D150 - 0.027

Test Parameters: All specimens are printed unless otherwise noted. All specimens were conditioned in ambient lab conditions at 19-23°C / 40-60% RH for at least 24 hours.

ASTM Methods: D638 Type IV, 5 mm/min, D790-B, 13 mm/min, D648, D256 Notched IZOD (Machine Notched), 6 mm x 12 mm, D570 0.125” x 2” Disc 24hr@ 25°C, D2240, Type “D” (3 seconds), D7867, D1475

Workflow and Printer Settings

Validated Workflow

To achieve the specified properties as provided in the Technical Data Sheet (TDS), which can be found HERE

It is crucial to follow validated workflows. Examples of validated workflow steps include:

  1. Ensure the use of a suitable industrial DLP printer.
  2. Follow safety protocols as outlined in the safety data sheet.
  3. Properly condition and handle the resin before printing.

Printer Settings

LOCTITE 3D MED3394 SHR BK is specifically formulated for optimal performance on industrial DLP printers. Please adhere to the following recommended print parameters to ensure the best results:

  • Shake the resin bottle well before use.
  • Maintain the temperature between 20°C and 35°C.
  • Set the light intensity between 3 mW/cm² and 7 mW/cm².
Back to top